Product Description
Feature:
LCD display with blue backlight,which is best care for you eyes.
Support for g, gn, oz, ozt, dwt, ct, meet your various need.
You can shutdown it by pressing the power switch,or it would power off in 1min without operation.
Have a large weighing range, the min capacity is 0.5g and the max capacity is 3000g.
Have automatic calibration function,you can calibrate the scale just with a weight.
Model |
SN-ES-P01 |
Capacity/accuracy |
1 2 3kg 500g/0.1g 0.01g |
Press Key |
ON/OFF key;units switch key, tare/zero key, counting key |
Display |
Lcd blue display |
Housing |
abs material |
Pan |
11CM*12CM stainless steel |
Battery |
2*AAA Battery |
Unit |
g, gn, oz, ozt, dwt, ct |
Low battery indication |
Lo |
Overload indication |
O-Ld |
Warranty |
12months |
OEM |
accept |
Detailed Photos
Operating instruction:
Put the scale on flat ground without vibration.
1.Press [ON/OFF] to start up.
2.When "0.00" or "0.0" shown on the LCD, press [M] or [Model] key to convert units.
3.Switch to the unit you need, put the goods on scale to weigh the weight.
II.Reset:
1.Put one tray or container on the platform.
2.Press [T] or [TARE] key, the"0.00" or "0.0" will be shown on LCD.
3.Then put goods in container or tray to weigh the weight.
III. Counting function:
The precondition of implementation counting function: each item to be weighed with the same weight.
1.Press [ON/OFF] to start up.
2.Long press[PCS] key, when sample data"25" shown on display, then press[M/Model] key to switch to the other sample data"60, 75, 100", after that put the same anount sample as shown.
3.Press [PCS] key to complete the sampling, then press [PCS] key again to count.
4.Put the goods in platform, and the amount of goods will be shown on display.
IV.Calibration:
All products have been calibrated before delivery, if this scale can not weigh normally, please calibrate again.
Weights used for calibration:3000g , 2000g , 1000g , 500g , 300g , 200g , 100g .
1.Long press[Model] key when it is on until the "CAL" shown on display, and then the nominal weighing data of this machine will be shown on display.
2.Put the weights with same weight of calibration on scale, then press [ON/OFF], [PASS] will be shown on display, complete calibration. This machine is in normal weighing state.
If "out2" shown on display when start up, please calibrate the scale again as follows:
1.Turn off the scale.
2.Press[ON/OFF] key and [MODE] key at the same time until a set of numbers shown on display, then press[ON/OFF] key, there will be "CAL" shown on display, after that a calibration weight will be shown on display.
3.Put the weights with same weight of calibration on center of platform, then press[ON/OFF] key.
4.When "PASS" shown on display, this machine is in normal weighing state. Calibration completed.
5.Solution to malfunction.
There are some reasons cause inaccurate weighing: low battery indication, incorrect calibration, the weight of goods exceeds the maxium range of scale and not weighing on the flat ground, ect.
Packaging & Shipping
1pc/gift box, 100pcs/ctn
Ctn size: 52x36X56cm
G.W./N.W.:11.0/10.0kgs
Certifications